Real Central Skylights Project · Niddrie VIC
Skylight Installation in Niddrie
A completed Niddrie project combining an old kitchen skylight replacement with a VELUX FS C06 fixed skylight and two rigid VELUX Sun Tunnels bringing daylight into the hallway.

Project overview
One home, two daylight solutions
This skylight installation in Niddrie addressed two separate areas. In the kitchen, the existing skylight was removed and replaced with a VELUX fixed skylight and a new plaster shaft. In the hallway, two rigid Sun Tunnels were installed to introduce overhead daylight through compact ceiling diffusers.
Kitchen replacement
Before and after: replacing the old kitchen skylight
The survey photo records the existing compact ceiling skylight. The later photo shows the new deeper plaster shaft formed beneath the replacement VELUX roof skylight, with plastering and sanding completed ready for the client’s painting.

Existing kitchen skylight before removal and replacement.

New skylight shaft after framing, plastering and sanding, ready for painting by the client.
Hallway daylight
Two rigid Sun Tunnels for the internal hallway
The hallway had limited direct daylight. Two 350 mm VELUX rigid Sun Tunnels were included in the job, with one 1240 mm rigid shaft extension specified where additional tube length was required.

Hallway ceiling during the pre-installation assessment, with the proposed daylight position marked.

Completed ceiling diffuser delivering overhead daylight into the hallway.
Installation journey
From roof-space assessment to finished roof work
The photographs document the real installation sequence: checking the roof cavity and intended positions, opening and framing the tiled roof, fitting the VELUX roof components, and completing the internal daylight openings.

Roof-space assessment
Existing timber framing and services were visible in the roof cavity and were considered when identifying practical installation positions.

Roof position confirmed
The proposed roof position was marked on the weathered profiled tiles before the roof opening was made.

Opening and framing
Tiles were removed around the opening and new timber framing was formed to receive the replacement skylight and internal shaft.

FS C06 and EDW flashing
The VELUX FS C06 fixed skylight was integrated into the pitched tile roof using the matching EDW C06 flashing system.

Two Sun Tunnel roof units
A wider roof view records the two separate Sun Tunnel roof collectors positioned along the tiled roof.

Internal shaft finished
The kitchen shaft was framed, plastered and sanded. Painting was outside the Central Skylights scope for this job.
Products & scope
VELUX products used on Job 59489
VELUX FS C06 fixed skylight
- 1 × FS C06 2004AD
- 550 × 1180 mm
- Fixed skylight for pitched roof application
- Matching EDW C06 flashing
- Existing kitchen skylight removed and disposed of
VELUX rigid Sun Tunnels
- 2 × TWR 0K14 2010
- 350 mm diameter
- Rigid shaft, listed at 1650 mm
- 1 × ZTR 0K14 0124 extension, 1240 mm
- Installed to hallway areas
Internal finishing & blind
- Framing and plastering to skylight shaft
- Roof cavity allowance listed up to 1500 mm
- Sanding included; painting excluded
- 1 × FSCD C06 1045KWL solar honeycomb blind included in the job scope
Project gallery
Roof, Sun Tunnel and interior details
Selected photographs are included because they explain the work clearly rather than simply increasing gallery size.





Why the combination works
Different daylight products for different spaces
The kitchen had an existing roof-light opening and was suited to a full-size VELUX fixed skylight replacement. The hallway needed compact daylight points rather than large plaster shafts, so rigid Sun Tunnels provided a separate solution for those internal areas.
For homeowners comparing options, Central Skylights can assess whether a room is better suited to a full skylight, a Sun Tunnel, or a combination of both.
Project scope at a glance
- Removal and disposal of the old kitchen skylight
- Supply and installation of one VELUX FS C06 fixed skylight
- VELUX EDW C06 flashing for the tiled roof
- Framing, plastering and sanding of the kitchen shaft
- Two rigid VELUX TWR 350 mm Sun Tunnels
- One rigid shaft extension where required
- Solar honeycomb blind included in the documented scope
Helpful next steps
Planning a similar skylight project?
Use the project details above as a real-world reference, then choose the information most useful for your own roof and room.
Skylights Melbourne
Central Skylights supply and installation information for Melbourne homeowners.
Visit Central Skylights →Installation services
See how roof installation, flashing and internal finishing can be handled as one project.
View services →Installation cost guide
Understand the main factors that affect skylight installation cost in Melbourne.
Read the guide →Completed projects
Browse more real Central Skylights installations across Melbourne.
View projects →Free home visit
Book an on-site assessment when your roof or ceiling needs to be seen in person.
Book a visit →Quote from photos
Send room, ceiling and roof photos for an initial skylight assessment.
Start online →Nearby areas
Skylight installation around Niddrie
Central Skylights also works across nearby north-west Melbourne suburbs.
Project FAQ
Skylight installation Niddrie: common questions
What skylight replaced the old kitchen skylight?
The documented replacement was one VELUX FS C06 2004AD fixed skylight, sized 550 × 1180 mm, with a matching VELUX EDW C06 flashing system.
Were Sun Tunnels installed as part of the same project?
Yes. The hallway scope included two VELUX TWR 0K14 rigid Sun Tunnels with 350 mm diameter shafts, plus one 1240 mm ZTR rigid extension.
Was the internal kitchen shaft plastered?
Yes. Framing, plastering and sanding were included. Painting was excluded and left for the client.
What roof type is shown in the project photographs?
The photographs show a pitched profiled tile roof. The exact tile material/profile and roof pitch are not confirmed by the project documents, so they are not specified more narrowly.
Can Central Skylights assess an old skylight replacement in Niddrie?
Yes. For replacement work, clear photos of the existing skylight, ceiling, roof and roof cavity where accessible help the team assess practical replacement options before quoting.
Niddrie & Melbourne
Planning a skylight replacement or a darker hallway?
Send photos for an online assessment or book a free home visit so the roof, ceiling and intended daylight positions can be reviewed.