Skip to content
Completed project · Job 57519

VELUX FCM Skylight Installation in St Kilda

A fixed VELUX FCM 3446 skylight installed over a bathroom on a low-pitch corrugated metal roof, finished with a custom Colorbond base flashing and backflashing system.

St Kilda, VICVELUX FCM 34461 fixed skylight5° metal roof
Completed VELUX FCM fixed skylight with custom Colorbond flashing on a corrugated metal roof in St Kilda
Project overview

A practical fixed skylight solution for a low-pitch bathroom roof

This St Kilda project involved installing a customer-supplied VELUX FCM 3446 fixed skylight. Central Skylights completed the roof installation, including the custom flashing and backflashing required to integrate the unit with the existing five-degree corrugated metal roof.

Product
VELUX FCM 3446
Nominal size
970 × 1275 mm
Location
Bathroom
Scope
Installation and flashing
Bathroom roof cavity and timber framing before the VELUX skylight was fitted in St Kilda
Before installation

Working with the existing roof structure

The project photographs show the underside of the roof framing before the skylight was installed. The selected position was prepared within the timber structure, allowing the new opening to be formed for the rectangular fixed skylight.

The photographs do not show a finished bathroom ceiling before the work, so this project is presented as an installation journey rather than a matched decorative before-and-after comparison.

Installation journey

From opening preparation to a weatherproof roof finish

The available photographs document the key roof-side stages of the work and the resulting daylight opening below.

Marked skylight opening position within the insulated timber roof framing
1

Opening set-out

The skylight position was marked within the roof framing to establish the opening and alignment.

Roof underlay prepared around the marked skylight opening on the low-pitch roof
2

Roof preparation

The roof area and underlay were prepared around the planned opening before the skylight and metal flashing were fitted.

VELUX FCM 3446 fixed skylight prepared before installation
3

Skylight prepared

The fixed VELUX FCM unit was checked and prepared for installation. The invoice confirms the 3446 size.

VELUX FCM skylight installed with custom flashing on corrugated Colorbond roofing
4

Custom metal flashing

A custom Colorbond base flashing was formed around the skylight, with backflashing continuing toward the higher roof junction.

Completed exterior VELUX FCM skylight installation on a five-degree corrugated roof in St Kilda
5

Completed roof finish

The finished exterior shows the fixed skylight seated neatly within the new corrugated metal roof section and surrounding flashing.

Daylight entering through the newly installed VELUX fixed skylight from inside the bathroom
6

Daylight opening below

The internal photograph confirms clear sky view and daylight through the new opening. Final ceiling and shaft finishing are not shown.

Technical details

Product, roof and flashing information

Confirmed from project documentation

  • One customer-supplied VELUX FCM 3446 fixed skylight
  • Nominal unit dimensions listed as 970 × 1275 mm
  • Installed for a bathroom at a residential property in St Kilda
  • Single-storey installation on a five-degree CGI/corrugated metal roof
  • Custom Colorbond flashing in Southerly colour
  • Two metres of installed Colorbond backflashing listed in the scope
  • Installation completed on 25 June 2026

What the photographs show

  • Timber roof framing and insulated roof cavity
  • Set-out and preparation of the roof opening
  • A low-pitch corrugated metal roof surface
  • Completed fixed skylight and formed metal flashing
  • Backflashing extending to the upper roof junction
  • Natural daylight visible through the internal opening
Why this method matters

Flashing designed for the actual roof

On a low-pitch corrugated roof, the skylight must be integrated with a flashing arrangement suited to the roof profile and water path. For this project, the documented scope included a custom Colorbond base flashing and backflashing rather than a standard pitched-roof tile flashing kit.

Homeowners comparing VELUX FCM fixed skylights can also review our skylight installation cost guide for the main factors that affect installation scope.

Close view of the custom Colorbond base flashing around the VELUX FCM skylight
Selected project photographs

Evidence from the St Kilda installation

Local experience

Skylight installation across inner Melbourne

Central Skylights completes skylight supply and installation work across Melbourne, including projects where a homeowner has already purchased a suitable unit and requires professional roof integration.

Why homeowners choose Central Skylights

  • Experience with VELUX fixed and opening skylights
  • Custom flashing solutions for corrugated metal roofs
  • Clear assessment of roof pitch, water flow and site access
  • Project-specific installation rather than a one-method-fits-all approach
  • Real completed-project examples across Melbourne

Nearby areas

We also service surrounding inner-south and bayside suburbs.

ElwoodBalaclavaWindsorPrahranSt Kilda EastAlbert ParkMiddle Park
Project FAQs

Questions about this St Kilda skylight project

Which skylight was installed?

The documentation identifies one VELUX FCM 3446 fixed skylight, with dimensions listed as 970 × 1275 mm.

Did Central Skylights supply the skylight?

No. The customer supplied the VELUX unit. Central Skylights completed the single-storey installation and the documented custom flashing work.

What roof type was involved?

The invoice identifies a five-degree CGI roof, and the photographs show a low-pitch corrugated metal roof.

Was the internal shaft fully finished?

The photographs show the daylight opening below the skylight, but they do not confirm completed plastering, sanding or painting. Those items are therefore not claimed as part of this case study.

Why was custom flashing used?

The project required the skylight to be integrated with a low-pitch corrugated roof. The documented scope included a custom Colorbond base flashing and backflashing suited to that roof arrangement.

Can Central Skylights install a customer-supplied skylight?

This project was installation-only for the skylight itself. Suitability still needs to be checked for each property, roof pitch, product and installation condition.

Planning a skylight installation in St Kilda?

Arrange a site visit so we can assess your roof, ceiling, preferred position and the most suitable installation method for your home.

Explore our skylight installation services or return to the Central Skylights Melbourne homepage.

Shopping cart0
There are no products in the cart!
Continue shopping
0